High Quality HVAC Systems from Mitsubishi

INDOOR UNITS

Wall-Mounted Units

MSY-GL24NA

COOL (BTU/H) 22500
HEAT (BTU/H) N/A
SEER 20.5
HSPF N/A
ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 34
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A, N
FAN SPEEDS 4 SPEED
TIMER 24H

MSZ-GL24NA

COOL (BTU/H) 22400
HEAT (BTU/H) 27600
SEER 20.5
HSPF 10
ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 32
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE E, N
FAN SPEEDS 3 SPEED
TIMER 24H

MSZ-FH18NA2

COOL (BTU/H) 17200
HEAT (BTU/H) 18000
SEER 22
HSPF 12
ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 25
I-SEE SENSOR OPTION YES
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A
FAN SPEEDS 5 SPEED
TIMER 24H

MSZ-EF18NAB

COOL (BTU/H) 17200
HEAT (BTU/H) 21600
SEER N/A
HSPF N/A
ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 30
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A
FAN SPEEDS 5 SPEED
TIMER WK, 24H

MSZ-EF18NAW

COOL (BTU/H) 17200
HEAT (BTU/H) 21600
SEER N/A
HSPF N/A
ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 30
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A
FAN SPEEDS 5 SPEED
TIMER WK, 24H

MSZ-EF18NAS

COOL (BTU/H) 17200
HEAT (BTU/H) 21600
SEER N/A
HSPF N/A
ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 30
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A
FAN SPEEDS 5 SPEED
TIMER WK, 24H

MSZ-EF18NAB

COOL (BTU/H) 22500
HEAT (BTU/H) N/A
SEER 20.5
HSPF N/A
ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 34
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A, N
FAN SPEEDS 4 SPEED
TIMER 24H

MSZ-EF18NAW

COOL (BTU/H) 33200
HEAT (BTU/H) 35200
SEER 14.5
HSPF 8.2
ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 32
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A, C
FAN SPEEDS 3 SPEED
TIMER 24H

Floor-Mounted

MSY-GL24NA

COOL (BTU/H) 17000
HEAT (BTU/H) 21000
SEER 21
HSPF 11.3
ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 26

I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE A, N
FAN SPEEDS 5 SPEED
TIMER WK, 24H, SL

Horizontal Ducted

MSZ-GL24NA

COOL (BTU/H) 17200
HEAT (BTU/H) 21600
SEER 17.5
HSPF 10
ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 30
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE F
FAN SPEEDS 3 SPEED
TIMER VARIES BY CONTROL

Ceiling Recessed

MSZ-FH18NA2

COOL (BTU/H) 15000
HEAT (BTU/H) 18000
SEER 16
HSPF 9.6
ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 31
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE F
FAN SPEEDS 4 SPEED
TIMER VARIES BY CONTROL

Air Handler

MSZ-EF18NAB

COOL (BTU/H) 36000
HEAT (BTU/H) 38000
SEER 19.3
HSPF 9.5
ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 30
I-SEE SENSOR OPTION NO
CONTROL OPTIONS AVAILABLE ALL
FILTER TYPE F
FAN SPEEDS 3 SPEED
TIMER VARIES BY CONTROL

OUTDOOR UNITS

Single-Zone

MUZ-GL24NA-U1

COOL (BTU/H) 22400

HEAT (BTU/H) 27600

SEER 20.5

HSPF 10

ENERGY STAR YES
SOUND LEVEL AS LOW AS DB(A) 55

HYPER-HEAT NO

MUZ-FH18NA2

COOL (BTU/H) 17200

HEAT (BTU/H) 20200

SEER 21

HSPF 12

ENERGY STAR YES

SOUND LEVEL AS LOW AS DB(A) 52

HYPER-HEAT YES

MUZ-HM18NA2

COOL (BTU/H) 17200

HEAT (BTU/H) 18000

SEER 18

HSPF 8.5

ENERGY STAR NO

SOUND LEVEL AS LOW AS DB(A) 49

HYPER-HEAT NO

MUZ-HM24NA2

COOL (BTU/H) 22500

HEAT (BTU/H) 26000

SEER 18

HSPF 8.5

ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 54

HYPER-HEAT NO

MUZ-D36NA-1

COOL (BTU/H) 33200

HEAT (BTU/H) 35200

SEER 14.5

HSPF 8.2

ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 56

HYPER-HEAT NO

Multi-Zone

MXZ-4C36NA2

COOL (BTU/H) 35400

HEAT (BTU/H) 36000

SEER 19.2

HSPF 11
MAX ZONES 4

ENERGY STAR NO
SOUND LEVEL AS LOW AS DB(A) 54

HYPER-HEAT NO

MXZ-5C42NA2

COOL (BTU/H) 40500

HEAT (BTU/H) 45000

SEER 19.7
HSPF 10.3

MAX ZONES 5

ENERGY STAR NO

SOUND LEVEL AS LOW AS DB(A) 56

HYPER-HEAT NO

MXZ-4C36NAHZ

COOL (BTU/H) 36000

HEAT (BTU/H) 45000

SEER 19.1
HSPF 11.3

MAX ZONES 4

ENERGY STAR YES

SOUND LEVEL AS LOW AS DB(A) 49

HYPER-HEAT YES

MXZ-8C60NA

COOL (BTU/H) 60000

HEAT (BTU/H) 66000

SEER 17.4

HSPF 10.5

MAX ZONES 8

ENERGY STAR YES

SOUND LEVEL AS LOW AS DB(A) 58

HYPER-HEAT NO

THERMOSTATS

MHK1

Number of Units Controllable 1

Fan Speed Settings 5 Speeds

Scheduling · Separate Heat/Cool scheduling
· Simple temperature setting can be done up to 4 times one day in the week. The time can be set by the 15-minute interval.

Optimal Start · Set occupied time and desired set temperature
· Remote controller learns when to start warm up or cool down so that space is at set temperature at start of occupied time

Additional Functions · Hold function
· Temporary Scheudle Override
· Reset to factory default

Auto Lock Out Function · Setting/releasing of simplified locking for remote control settings can be performed.
· Locking of all settings
· Locking of ON/OFF setting
· Locking of system
· Locking of fan setting
· Locking of temperature
· Locking of Clock/Day/Schedule


CALL NOW:
(904) 783-7003

SCHEDULE
APPOINTMENT